- 锐高
- 产品
- LED驱动
- 产品检索
- 第四代
- companionSUITE software
- Outdoor致密型调光
- Outdoor linear IP67/IP66 dimming
- 室外线性IP67固定输出
- Industry线性/区域 调光
- Industry线性/区域 固定输出
- 线性调光 SELV
- 线性调光 non-SELV
- 线性固定输出 SELV
- 线性固定输出 non-SELV
- excite
- LC 25 W 75–350 mA flexC NF h16 EXC4
- LC 40 W 75–400 mA flexC NF h16 EXC4
- LC 60 W 75–330 mA flexC NF h16 EXC4
- LC 60 W 150–550 mA flexC NF h16 EXC4
- LC 90 W 150–400 mA flexC NF h16 EXC4
- LC 90 W 200–800 mA flexC NF h16 EXC4
- LC 120 W 350-1050 mA flexC NF h16 EXC4
- LC 50 W 100–400 mA flexC lp EXC
- LC 75 W 100–400 mA flexC lp EXC
- LC 75 W 250–550 mA flexC lp EXC
- LC 75 W 350–1050 mA flexC lp EXC
- LC 100 W 250–700 mA flexC lp EXC
- advanced
- essence
- essence (stepDIM)
- excite
- 紧凑型调光驱动
- 紧凑型固定输出驱动
- in-track dimming
- in-track fixed output
- DC-String
- 恒压驱动器
- Universal wide voltage (UNV)
- Matter components
- 配件
- LED模组
- Tunable White
- 应急照明装置
- 灯光控制与连接
- LED驱动
- 应用领域
- 互联网照明
- 案例
- 服务
- 技术参数
- 联系
- 主页
- 产品
- ►
- LED驱动
- ►
- 线性固定输出 non-SELV
- ►
- excite
- ►
- LC 120 W 350-1050 mA flexC NF h16 EXC4
Driver LC 120W 350–1050mA flexC NF h16 EXC4
excite标准版系列
产品描述
- New article with updated NFC interface for combability with ID ECCO Smart 2D-TR
- 用于灯具安装的恒流LED驱动
- 匹配I类灯具使用
- 使用 NFC 时,输出电流可在 350-1,050 毫安之间调节
- 最大输出功率120W
- 效率高达 93%
- 高达100,000小时的额定寿命
- 5 年保修(保修条件请参见 www.tridonic.com)
外壳特性
- 带白色盖的薄型金属外壳
- 仅 16 毫米外壳高度
- 安全等级IP20
接口
- 近场通信 (NFC)
- 端口:0° 推入式端口
功能
- 可按 1 毫安步进调节输出电流 (NFC)
- 恒定光输出功能 (eCLO)
- 保护功能(过热、短路、过载、空载)
- 智能电压保护(过压和欠压监控)
- 适用于符合 EN 50172 的应急照明系统
优点
- 通过 companionSUITE 灵活配置
- 支持 NFC 多重编程(整个纸箱单元)
- 具备最大兼容性并以应用为主导的操作窗口
- 高效率实现最佳节能效果
- 高达 100,000 小时的使用寿命和 5 年质保(有关条件,请参见 www.tridonic.com)。
典型应用
- 为了在办公应用里线性或大面积照明
Ordering data | ||||
---|---|---|---|---|
Type | Article number | Packaging, carton | Packaging, pallet | Weight per pc. |
LC 120/350-1050/240 flexC NF h16 EXC4 | 28004330 | 10 pc(s). | 950 pc(s). | 0.200 kg |
LC 120/350-1050/240 flexC NF h16 EXC4 | 28005039 | 10 pc(s). | 950 pc(s). | 0.196 kg |
- Luminaire types:
-
-
-
-
- Certificates:
-
-
-
-
-
-
-
-
-
-
-
Technical data | |
---|---|
Rated supply voltage | 220 – 240 V |
交流电压范围 | 198 – 264 V |
DC voltage range | 176 – 280 V |
Mains frequency | 0 / 50 / 60 Hz |
Overvoltage protection | 320 V AC, 48 h |
Typ. rated current (at 230 V, 50 Hz, full load) (1) | 560 mA |
Typ. current (220 V, 0 Hz, full load) (1) | 580 mA |
Leakage current (at 230 V, 50 Hz, full load) (1) | < 700 µA |
Max. input power | 128 W |
Output power range (P_rated) | 77 – 120 W |
Typ. efficiency (at 230 V, 50 Hz, full load) (1) | 93 % |
λ (at 230 V, 50 Hz, full load) | 0.99 |
λ (over full operating range) | 0.7C – 0.99 |
Typ. input current in no-load operation | 46.9 mA |
Typ. input power in no-load operation | 0.85 W |
In-rush current (peak / duration) | 51.4 A / 143 µs |
THD (at 230 V, 50 Hz, full load) | < 10 % |
Starting time (at 230 V, 50 Hz, full load) | < 300 ms |
Starting time (DC mode) | < 500 ms |
Switchover time (AC/DC) (2) | < 500 ms |
Turn off time (at 230 V, 50 Hz, full load) | < 30 ms |
Output current tolerance (3) | ± 5 % |
Max. output current peak (non-repetitive) | ≤ output current + 90 % |
Output LF current ripple (< 120 Hz) | ± 3 % |
Output P_ST_LM (at full load) | ≤ 1 |
Output SVM (at full load) | ≤ 0.4 |
Max. output voltage (U-OUT) | 250 V |
Mains surge capability (between L - N) | 1 kV |
Mains surge capability (between L/N - PE) | 2 kV |
Burst / surge peaks output side against PE | ≤ 2.5 kV |
保护类型 | IP20 |
寿命 | up to 100,000 h |
Guarantee (conditions at www.tridonic.com) | 5 Year(s) |
尺寸 长 x 宽 x 高 | 360 x 30 x 16.3 mm |
Specific technical data | ||||||||
---|---|---|---|---|---|---|---|---|
Type | Output current (1) (2) | Min. output voltage | Max. output voltage | Max. output power | Typ. power consumption (at 230 V, 50 Hz, full load) | Typ. current consumption (at 230 V, 50 Hz, full load) | tc point max. | 环境温度 ta |
LC 120/350-1050/240 flexC NF h16 EXC4 | 350 mA | 45 V | 220.0 V | 77 W | 80.2 W | 360 mA | 70 °C | -20 ... +60 °C |
LC 120/350-1050/240 flexC NF h16 EXC4 | 400 mA | 45 V | 220.0 V | 88 W | 91.7 W | 410 mA | 70 °C | -20 ... +60 °C |
LC 120/350-1050/240 flexC NF h16 EXC4 | 450 mA | 45 V | 220.0 V | 99 W | 102.6 W | 457 mA | 70 °C | -20 ... +60 °C |
LC 120/350-1050/240 flexC NF h16 EXC4 | 500 mA | 45 V | 220.0 V | 110 W | 114.6 W | 509 mA | 75 °C | -20 ... +60 °C |
LC 120/350-1050/240 flexC NF h16 EXC4 | 550 mA | 45 V | 218.2 V | 120 W | 124.3 W | 551 mA | 75 °C | -20 ... +60 °C |
LC 120/350-1050/240 flexC NF h16 EXC4 | 600 mA | 45 V | 200.0 V | 120 W | 124.7 W | 553 mA | 75 °C | -20 ... +60 °C |
LC 120/350-1050/240 flexC NF h16 EXC4 | 650 mA | 45 V | 184.6 V | 120 W | 124.3 W | 550 mA | 75 °C | -20 ... +60 °C |
LC 120/350-1050/240 flexC NF h16 EXC4 | 700 mA | 45 V | 171.4 V | 120 W | 125.0 W | 553 mA | 80 °C | -20 ... +60 °C |
LC 120/350-1050/240 flexC NF h16 EXC4 | 750 mA | 45 V | 160.0 V | 120 W | 125.5 W | 556 mA | 80 °C | -20 ... +60 °C |
LC 120/350-1050/240 flexC NF h16 EXC4 | 800 mA | 45 V | 150.0 V | 120 W | 126.2 W | 559 mA | 80 °C | -20 ... +60 °C |
LC 120/350-1050/240 flexC NF h16 EXC4 | 850 mA | 45 V | 141.2 V | 120 W | 126.7 W | 562 mA | 80 °C | -20 ... +60 °C |
LC 120/350-1050/240 flexC NF h16 EXC4 | 900 mA | 45 V | 133.3 V | 120 W | 127.4 W | 564 mA | 80 °C | -20 ... +60 °C |
LC 120/350-1050/240 flexC NF h16 EXC4 | 950 mA | 45 V | 126.3 V | 120 W | 129.3 W | 572 mA | 82 °C | -20 ... +55 °C |
LC 120/350-1050/240 flexC NF h16 EXC4 | 1,000 mA | 45 V | 120.0 V | 120 W | 128.3 W | 568 mA | 82 °C | -20 ... +55 °C |
LC 120/350-1050/240 flexC NF h16 EXC4 | 1,050 mA | 45 V | 114.3 V | 120 W | 128.0 W | 567 mA | 82 °C | -20 ... +55 °C |
LC 120/350-1050/240 flexC NF h16 EXC4 | 350 mA | 45 V | 220.0 V | 77 W | 80.2 W | 360 mA | 70 °C | -20 ... +60 °C |
LC 120/350-1050/240 flexC NF h16 EXC4 | 400 mA | 45 V | 220.0 V | 88 W | 91.7 W | 410 mA | 70 °C | -20 ... +60 °C |
LC 120/350-1050/240 flexC NF h16 EXC4 | 450 mA | 45 V | 220.0 V | 99 W | 102.6 W | 457 mA | 70 °C | -20 ... +60 °C |
LC 120/350-1050/240 flexC NF h16 EXC4 | 500 mA | 45 V | 220.0 V | 110 W | 114.6 W | 509 mA | 75 °C | -20 ... +60 °C |
LC 120/350-1050/240 flexC NF h16 EXC4 | 550 mA | 45 V | 218.2 V | 120 W | 124.3 W | 551 mA | 75 °C | -20 ... +60 °C |
LC 120/350-1050/240 flexC NF h16 EXC4 | 600 mA | 45 V | 200.0 V | 120 W | 124.7 W | 553 mA | 75 °C | -20 ... +60 °C |
LC 120/350-1050/240 flexC NF h16 EXC4 | 650 mA | 45 V | 184.6 V | 120 W | 124.3 W | 550 mA | 75 °C | -20 ... +60 °C |
LC 120/350-1050/240 flexC NF h16 EXC4 | 700 mA | 45 V | 171.4 V | 120 W | 125.0 W | 553 mA | 80 °C | -20 ... +60 °C |
LC 120/350-1050/240 flexC NF h16 EXC4 | 750 mA | 45 V | 160.0 V | 120 W | 125.5 W | 556 mA | 80 °C | -20 ... +60 °C |
LC 120/350-1050/240 flexC NF h16 EXC4 | 800 mA | 45 V | 150.0 V | 120 W | 126.2 W | 559 mA | 80 °C | -20 ... +60 °C |
LC 120/350-1050/240 flexC NF h16 EXC4 | 900 mA | 45 V | 133.3 V | 120 W | 127.4 W | 564 mA | 80 °C | -20 ... +60 °C |
LC 120/350-1050/240 flexC NF h16 EXC4 | 950 mA | 45 V | 126.3 V | 120 W | 129.3 W | 572 mA | 82 °C | -20 ... +55 °C |
LC 120/350-1050/240 flexC NF h16 EXC4 | 1,000 mA | 45 V | 120.0 V | 120 W | 128.3 W | 568 mA | 82 °C | -20 ... +55 °C |
LC 120/350-1050/240 flexC NF h16 EXC4 | 1,050 mA | 45 V | 114.3 V | 120 W | 128.0 W | 567 mA | 82 °C | -20 ... +55 °C |
认证 / 符合性声明 | ||
型号 | 物品号 | 认证 |
---|---|---|
认证 () |